Fuses - 5 x 20mm (EUR VERSION)
| FSD/FSD-P
Fuses - 5 x 20mm (EUR VERSION)
|
 |
|
Fast Acting/Glass Construction
A cost-effective fast-acting fuse for use in all low interrupting capacity
applications in global markets beyond North America. |
Electrical Specifications
125mA-16A 250VAC
| Time Characteristics |
| 150% |
1h |
min. hold time |
| 210% |
0.5h |
max. hold time |
| 275% |
50ms 2s |
min. hold time max. hold time |
| 400% |
10ms 300ms |
min. hold time max. hold time |
| 1000% |
20ms |
max. hold time |
Agency Standards
& Listings
IEC 127-2 Sheet II (125mA-6.3A)
UL Recognized (125mA-6.3A)
|
|
|
FCD/FCD-P
Fuses
-
5 x 20mm (EUR VERSION)
|
 |
|
Fast Acting/Ceramic Construction
A cost-effective fast-acting fuse for use in higher
interrupting capacity applications in global markets
beyond North America.
|
Electrical Specifications
125mA-16A 250VAC
| Time Characteristics |
| 150% |
1h |
min. hold time |
| 210% |
0.5h |
max. hold time |
| 275% |
10ms 2s 3s |
min. hold time max. hold time (125mA-3.15A) max. hold time (3.5A-6.3A) |
| 400% |
3ms 300ms |
min. hold time max. hold time |
| 1000% |
20ms |
max. hold time |
Agency Standards
& Listings
IEC 127-2 Sheet I (125mA-6.3A)
UL Recognized (125mA-6.3A)
|
|
|
TSD/TSD-P Fuses -
5 x 20mm (EUR VERSION)
|
 |
|
Time Delay/Glass Construction
A cost effective time-delay fuse for use in all low
interrupting capacity applications with higher in-rush
currents in global markets beyond North America.
|
Electrical Specifications 125mA-16A 250VAC
| Time Characteristics |
| 150% |
1h |
min. hold time |
| 210% |
120s |
max. hold time |
| 275% |
600ms 10s |
min. hold time max. hold time |
| 400% |
150ms 3s |
min. hold time max. hold time |
| 1000% |
20ms 300ms |
min. hold time max. hold time |
Agency Standards
& Listings
IEC 127-2 Sheet III (125mA-6.3A)
UL Recognized (125mA-6.3A)
|
|
| TCD/TCD-P
Fuses
-
5 x 20mm (EUR VERSION)
|
 |
|
Time Delay/Ceramic Construction
A cost-effective time-delay fuse for use in higher
interrupting capacity applications with higher in-rush
currents in global markets beyond North America.
|
Electrical Specifications
125mA-16A 250VAC
| Time Characteristics |
| 150% |
1h |
min. hold time |
| 210% |
0.5h |
max. hold time |
| 275% |
1s 80s |
min. hold time max. hold time |
| 400% |
95ms 150ms 5s |
min. hold time (125mA-3.15A) min. hold time (3.5A-6.3A)
max. hold time |
| 1000% |
10ms 20ms 15s 1s |
min. hold time (125mA-3.15A) min. hold time (3.5A-6.3A)
max. hold time (125mA-400mA) max. hold time (500mA-6.3A) |
Agency Standards & Listings
IEC 127-2 Sheet V (125mA-6.3A)
|
|
|