| APR Fuses - Regular Automotive Blade |
 |
Fast Acting/Blade Mounting
A cost-effective standard automotive fuse for use in automotive, battery and general DC applications. |
Electrical Specifications
1A-40A 32VDC
Design Standards
SAE J1284
| Time Characteristics |
| 110% |
100h |
min. hold time |
| 135% |
750ms
.5h |
min. hold time
max. hold time |
| 200% |
150ms
5s |
min. hold time
max. hold time |
| 350% |
80ms
250ms |
min. hold time
max. hold time |
| 600% |
30ms
100ms |
min. hold time
max. hold time |
Amperage -- (1, 2, 3, 4, 5, 7.5, 10, 15, 20, 25, 30, 40)A *
* see color chart at the top right portion of screen
| APR-UL Fuses - Regular Automotive Blade |
 |
Fast Acting/Blade Mounting
A cost-effective standard automotive fuse for use in automotive, battery and general DC applications requiring UL approval. |
Electrical Specifications
1A-40A 32VDC
Design Standards
ISO 8820-3 UL 284
| Time Characteristics |
|
% of Rated Current
|
Opening
Time
|
Min Hold
Time
|
Max Hold
Time
|
|
100%
|
35-40
|
100h
|
-
|
|
110%
|
1-30
|
100h
|
-
|
|
135%
|
1-2
3-40
|
500ms
750ms
|
600ms
600ms
|
|
200%
|
1-2
3-40
|
100ms
150ms
|
5s
5s
|
|
350%
|
1-2
3-40
|
20ms
80ms
|
500ms
500ms
|
|
600%
|
1-30
35-40
|
-
-
|
100ms
150ms
|
Agency Standards & Listings
 |
|
Amperage -- (1, 2, 3, 4, 5, 7.5, 10, 15, 20, 25, 30, 35, 40)A *
* see color chart at the top right portion of screen
| APR-I Fuses - Regular Automotive Blade with LED |
 |
Fast Acting/Blade Mounting
A standard size automotive blade fuse with LED Indicator for easy open fuse indication. |
Electrical Specifications
2A-40A 32VDC
Design Standards
SAE J1284
| Time Characteristics |
| 110% |
4h |
min. hold time |
| 135% |
750ms
30m |
min. hold time
max. hold time |
| 200% |
150ms
5s |
min. hold time
max. hold time |
Amperage -- (5, 7.5, 10, 15, 20, 25, 30)A *
* see color chart at the top right portion of screen
| APR58 Fuses - Regular Automotive Blade |
 |
Fast Acting/Blade Mounting
A regular size automotive blade fuse for use in 42V automotive systems. |
Electrical Specifications
500mA-40A 58VDC
Design Standards
SAE J1284
| Time Characteristics |
| 110% |
>100h |
min. hold time |
| 135% |
750ms
1800s |
min. hold time
max. hold time |
| 200% |
150ms
5s |
min. hold time
max. hold time |
| 350% |
40ms
500ms |
min. hold time
max. hold time |
| 600% |
20ms
100ms |
min. hold time
max. hold time |
Amperage -- (500m, 1, 2, 3, 4, 5, 7.5, 10, 15, 20, 25, 30,35, 40)A *
* see color chart at the top right portion of screen
|
| Amperage |
Body Color |
| 500mA |
Dark Blue |
| 1A |
Black |
| 2A |
Gray |
| 3A |
Violet |
| 4A |
Pink |
| 5A |
Tan |
| 7.5A |
Brown |
| 10A |
Red |
| 15A |
Blue |
| 20A |
Yellow |
| 25A |
Clear |
| 30A |
Green |
| 35A |
Blue Green |
| 40A |
Orange |
|